WHAT HAPPENS INSIDE MAKES IT SAFE OUTSIDE

As an ion chromatographer, the routine IC applications you run give the rest of us the peace of mind to use everyday resources like water, food and beverages, biofuels and pharmaceuticals without a second thought.

Nothing supports you in this role more than your laboratory instruments. The Thermo Scientific™ Dionex™ Integrion™ HPIC™ system is designed to be your reliable partner.

  • Easy-to-install fittings
  • Logical, flow-based plumbing layout
  • Whole-system smart monitoring*

* The wireless transmitter devices may not be authorized as required by the laws of your country; and these features will not be, offered for sale or lease, or sold or leased, until proper authorization is obtained. Please consult your local sales representative for details. Click here for more information about wireless service in your area.

 Learn More  Explore the Instrument

Consistency is key. The Dionex Integrion IC system provides stability and control for variables that might affect the quality and consistency of your results.

  • Greater flexibility to choose the right detector or column format for your application
  • Two different models to choose from
  • Wide range of configurations

Contact Us


Derivitization-free Analysis of Simple Sugars
in Foods and Beverages using HPAE-PAD

On-Demand Webinar

During this event, Dr. Jeffrey Rohrer discusses the benefits of using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAE-PAD) for sugar analysis.

Watch Now

AN INSTRUMENT WORTH GETTING TO KNOW

A DESIGN THAT SEAMLESSLY BLENDS INTO YOUR LAB

Your laboratory ecosystem is different from all others. It consists of its own unique web of interactions between your laboratory team and the instruments they use.

At its best, everything is in sync. Thoughtfully designed instruments accelerate your stream of results while blending seamlessly into your laboratory. The Dionex Integrion IC system is made to support you. It was designed to fit with the flow of your laboratory so that it quickly falls in sync with your processes.

Simplified plumbing layout with integrated architecture

Layout based on logical flow-path for easy component access in a compact platform with a small physical footprint.

Consumables Device Monitor*

Provides positive identification of a consumable's performance metrics, preventing consumable installation errors and mismatches by automatically logging consumable use and performance.

Detachable tablet* with local language support

Flexible access to IC controls that speak your language.

* The wireless transmitter devices may not be authorized as required by the laws of your country; and these features will not be, offered for sale or lease, or sold or leased, until proper authorization is obtained. Please consult your local sales representative for details. Click here for more information about wireless service in your area.

Upgradeable features

In a fluid market with changing demands, the Dionex Integrion IC system offers a wide range of upgradable components, so it can grow with your needs over time.

  • Electrolytic sample preparation
  • Electrolytic water purification

Automated Eluent Generation (EG™)

Eliminate human errors associated with manual eluent preparation and improve method reproducibility from operator-to-operator and lab-to-lab. The Dionex Integrion IC system brings consistent results to all your applications. In this case, 100 injections of a simple sugar mixture are highly reproducible.

Wide range of column support

Choose the column sizes you need for your applications, including smaller-particle-size 4 µm columns that provide faster run times and better resolution.

EXPLORE

Click drag to rotate
Click to open doors

Eluent Generation

Better method reproducibility using Automated Eluent Generation (EG™)

Mobile Instrument Control

Flexible access to IC controls and at-instrument viewing of additional troubleshooting and installation resources

Features:
  • Multi-language support
  • Built-in mobile device charging
  • Operational at a range up to 30 ft
  • Secured WiFi communication*

* The wireless transmitter devices may not be authorized as required by the laws of your country; and these features will not be, offered for sale or lease, or sold or leased, until proper authorization is obtained. Please consult your local sales representative for details. Click here for more information about wireless service in your area.

CR-TC hinged to allow access to EGC

Simplified plumbing layout, optimized for minimal tubing dead volume, while allowing access to EGC fittings

Eluent Degasser

Helps prevent bubbles forming in the eluent proportioning valves, pump heads and the detector cell

Features:
  • Additional vacuum pump outlet available at the back

HPIC Pump

High-performance pump up to 6000 psi

Features:
  • Flow rates from 0.001 – 10 mL/min
  • Low pulsation
  • Metal-free PEEK pump heads and flow path
  • Optional piston seal wash

Eluent Shut-Off Valve

Stops eluent flow when pump is off and allows for plumbing and replacing consumables without fluid leaks

Changeable Detectors

Thermostatted detector compartment allows tight environmental control for optimal performance

Features:
  • Temperature range: 15-40°C
Resources
Product Spotlight: Electrochemical Detection

Manual Injection Port

Easy access for manual injections, including convenient vial holder

Consumables Device Monitor

Labor-free consumables performance and usage tracking

Features:
  • Over 20 operational parameters tracked
  • Up to seven consumables simultaneously monitored
  • Information stays with the consumable
Resources
Product Spotlight – Consumables Monitoring

Auxiliary Injection Valve

Optional control of an additional high-pressure Rheodyne valve used for sample preparation

Features:
  • 6-port or 10-port valves

Column Oven

Provides precise temperature control over a wide temperature range with extremely fast heat-up times

Features:
  • 30-80°C, minimum 5 °C above ambient
  • Time to temperature: 20 min


See the Instrument In Action

View a short animation on the inner workings of the Thermo Scientific™ Dionex™ Integrion™ HPIC™ system

Watch the Video

WHAT'S INSIDE MATTERS

AN IC INSTRUMENT THAT QUICKLY FEELS LIKE AN OLD FRIEND

As lab professionals, you spend a lot of time interacting with laboratory instruments. They are your partners, working with you towards the same goal. This is why the Dionex Integrion IC system is designed to be an instrument that you can quickly get to know. The entire user interface is intuitive to navigate, even if you are new to ion chromatography.

In order to meet today’s demands, you need an IC instrument with high throughput capability, that quickly recovers from setbacks. The Dionex Integrion IC system is always ready for action, keeping your lab continuously flowing. It boosts throughput with a high-pressure capable system and is equipped with whole-system monitoring, allowing you to focus on results without interruption.

Intuitive user interface

Clearly presented control of IC instruments with extensible software for additional troubleshooting, installation and application support.

IC PEEK Viper Fittings

Simple-to-install fittings that have low dead volume and require no extra training or tools.

Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System (CDS) Software

The natural complement to your IC system is a software platform that streamlines your path from samples to results quickly and easily, boosting your overall lab productivity

RESOURCES

Designed to be familiar and flexible, the Thermo Scientific™ Dionex™ Integrion™ HPIC™ System has the reliability you need for consistent results from day to day and operator to operator. Download or visit the resources below to learn more about the features and capabilities of this state-of-the-art system.

Environmental


Food and Beverage


Pharmaceutical


Industrial and Petrochemical

Fast, Cost-effective IC Methods for Compliance Testing of Environmental Waters

On-Demand Webinar

During this event, we will discuss regulatory compliance testing of municipal drinking water and wastewater, and how this testing can be made faster and more cost-effective through the use of high-pressure-capable ion chromatography systems.

Watch Now

Derivitization-free Analysis of Simple Sugars in Foods and Beverages using HPAE-PAD

On-Demand Webinar

During this event, Dr. Jeffrey Rohrer discusses the benefits of using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAE-PAD) for sugar analysis.

Watch Now

3D Animation - See the Instrument In Action

View a 3 minute animation on the inner workings of the Thermo Scientific™ Dionex™ Integrion™ HPIC™ system.

Introduction to Ion Chromatography

Learn the basics of ion chromatography including an introduction to our latest system.

Eluent Generation for Ion Chromatography

This whiteboard video discusses the role of eluents and eluent generation in separating compounds via ion chromatography.


Consumables Device Monitor FAQ

Consumables Device Monitor is a new instrument feature available on the Thermo Scientific™ Dionex™ Integrion™ HPIC™ system. Each consumable ships with a memory tag:

  • Electrolytic consumables include a memory chip in the cable.
  • Non-electrolytic consumables include a wireless RFID tag in the product label.

When a consumable is added to the system, the instrument controller detects the presence of the consumable and downloads the stored data from the memory tag. The instrument controller can communicate with these tags to identify the consumables installed on the instrument and subsequently store operational and performance metrics to the tag memory.

During production, a comprehensive set of specification data, listed below, is written onto each device before it is shipped to users. This data includes:

  • Product identification
  • Serial and lot numbers
  • Use-by date
  • Column diameters
  • Other device specifications
  • Quality Assurance Report (QAR), results also stored for separator columns

This data can be easily retrieved from the front panel tablet app or by using the Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System (CDS) software. The Chromeleon CDS software also includes a feature to directly compare results obtained locally against reported QAR data.

When a consumable is placed in the system for the first time, the current date and time is written to the memory tag. Hence, the instrument controller can determine exactly how long a consumable has been in commission.

During operation, the instrument controller will write the key performance metrics noted below to the memory tag as they are collected. This data is regularly updated by the system ensuring it is up to date and valid. Key metrics include:

  • Date of first install
  • Number of injections
  • Key metric maxima
  • Last columns paired with
  • Key metric tallies
  • Eluent types
  • Ion count
  • Key metric trend data

The Chromeleon CDS software is programmed with a set of predefined configuration rules. If any of the detected consumables break these rules, a warning is sent to the Audit Trail and the Consumables Inventory page. The warning notifies the operator that the detected set of consumables contains at least one mismatch. It will not prevent the system from operating if the mismatch was intentional.

Two configuration restrictions are monitored:

  • Size mismatches, such as combining 4 mm and 2 mm consumables
  • Chemistry mismatches, such as anion and cation

The Consumables Device Monitor feature is functional only on IC consumables shipped after February 1st, 2016 for use on the Dionex Integrion HPIC system.

The Thermo Scientific Dionex EGC, EGC II, CR-TC, CR-TC II and CR-TC 500 consumables are not compatible with systems equipped with the Consumables Device Monitoring feature, such as the Dionex Integrion HPIC system. The Dionex EGC III, EGC 500 and CR-TC 600 consumables are required.

From February 2016, all consumables with the memory tag installed will include an "RFID Ready" or "Device Monitoring Enabled" message on the label, and will be shipped with a system ordered on the same sales order.

Existing data will be transferred to the second system and new data appended ONLY if it also supports the Consumable Device Monitoring feature. However, the initial installation date will not be updated.



Chris Pohl

Vice President, Chromatography Chemistry
Thermo Fisher Scientific

David Moore

Manager of Product Management
Thermo Fisher Scientific

Joachim Weiss

Technical Director, Dionex Products
Thermo Fisher Scientific

TESTIMONIALS

"There should be no other way than Automated Eluent Generation."

Amie Myers
Vice President
Microconsult, Inc

"I like the (system) accessibility"

Power Industry Employee




"Our work has relied on high-performance ion chromatography for the detail and precision it provides. The new Integrion system combines the best features of HPIC in a compact format that is easy to use. The single channel pump design with inline eluent generation makes it easy to instantly have a range of hydroxide eluent strengths and gradients without having to worry about the reproducibility issues with carbonate contamination."

Klaus Englyst
Managing Director
Englyst Carbohydrates Ltd, United Kingdom



"We can use the IC columns with smaller particle sizes to obtain better results."

Prof. Cai Yaqi
Research Center for Eco-Environmental Sciences
Chinese Academy of Science

"You can train staff easily on this system."

Karam Wadi
Technologist, Analytica Laboratories Ltd
Ruakura Research Centre, New Zealand





"The Consumables Device Monitor helps us ensure that IC consumables are ordered well before they are needed, minimizing system downtime. This feature also helps us anticipate potentially time-consuming maintenance requirements (e.g., rebuilding a pump) in advance of inconvenient malfunctions."

Timothy Veverica
Analytical Chemist
UMBS



"The Dionex Integrion HPIC system brings big improvements in the area of increased productivity in our lab."

Dr. Gisele Birman Tonietto
Coord. Apolo a Projectos de Pesquisa LABAGUAS - Lab
De Caracterização de Águas PUC-Rio

Talk to an expert about the Thermo Scientific Dionex Integrion HPIC System

Let us answer your questions about the new Thermo Scientific™ Dionex™ Integrion™ HPIC™ system. Fill out the form below and we will have an expert get in touch with you shortly.

Thank you for your interest

Thermo Fisher Scientific is excited that you are interested in the Dionex™ Integrion™ HPIC™ system! One of our experts will contact you shortly.

Close

Talk to an expert about the Thermo Scientific Dionex Integrion system

Provide your contact information and we will have one of our experts contact you to answer any questions you may have about the Thermo Scientific™ Dionex™ Integrion™ HPIC™ system.

Thank you for your interest

Thermo Fisher Scientific is excited that you are interested in the Dionex Integrion system! One of our experts will contact you shortly.

Close

Receive a demo of the Thermo Scientific Dionex Integrion system

Want to see the system in person? Sign up to see how the Thermo Scientific Dionex Integrion system can help solve your toughest scientific challenges!

Thank you for your interest

Thermo Fisher Scientific is excited that you are interested in the Dionex Integrion system! One of our experts will contact you shortly.

Close